BACKGROUND: Kathon CG is a commonly used cosmetic-grade preservative that contains active ingredients methylchloroisothiazolinone (MCI) and methylisothiazolinone (MI). OBJECTIVE: The aim of the study was to perform a skin sensitization induction risk assessment of daily exposure to Kathon CG after use of various personal care and cosmetic products. METHODS: We calculated an estimated daily consumer exposure level for rinse-off and leave-on products using the amount of product applied per application, number of applications per day, a retention factor, the MCI/MI concentration, and body surface area values. We assumed that the products contained the maximum recommended safe concentration of MCI/MI: 15 ppm in rinse-off products and 7.5 ppm in leave-on products. We compared estimated consumer exposure levels with the no expected sensitization induction level for MCI/MI and applied sensitization assessment factors to calculate product-specific margins of safety (MOSs). CONCLUSIONS: The MOSs for rinse-off products ranged from 5 to 63, whereas the MOSs for leave-on products ranged from 0.03 to 1.49. Overall, our results provide evidence that some leave-on products containing the maximum recommended safe concentration of Kathon CG may increase the risk of sensitization induction due to exposure to MCI/MI. In contrast, rinse-off products were not associated with a potential increased risk of skin sensitization induction.